For feedback, use the following:
ipd_online_feedback@alcatel-lucent.com
Table of Contents Previous Next Index PDF


Show Commands
alarms
Syntax 
alarms [cleared] [severity severity-level] [count count] [newer-than days]
Context 
show>system
Description 
This command displays facility alarms on the system.
Output 
Facility Alarm Output
The following table describes the alarms output fields.
Sample Output
A:Dut-A# show system alarms
 
===============================================================================
Alarms [Critical:1 Major:2 Minor:0 Warning:0 Total:3]
===============================================================================
Index      Date/Time               Severity     Alarm         Resource
   Details
-------------------------------------------------------------------------------
8          2011/04/01 18:36:43.80  MAJOR        7-2011-1      Power Supply 1
   Power supply 1, power lost
 
7          2011/04/01 18:35:57.00  MAJOR        7-2005-1      Chassis 1
   Chassis 1: temperature too high
 
6          2011/04/01 18:35:24.80  CRITICAL     7-2006-1      Fan 1
   Fan 1 failed
===============================================================================
 
 
Cleared alarms table:
 
A:Dut-A# show system alarms cleared
 
===============================================================================
Cleared Alarms [Size:500 Total:5 (not wrapped)]
===============================================================================
Index      Date/Time               Severity     Alarm         Resource
   Details
-------------------------------------------------------------------------------
5          2011/04/01 18:11:55.00  MAJOR        7-2005-1      Chassis 1
   Clear Chassis temperature too high alarm
 
3          2011/04/01 18:11:54.50  CRITICAL     7-2051-1      Power Supply 1
   Clear Power Supply failure
 
2          2011/04/01 18:11:54.40  CRITICAL     7-2050-1      Power Supply 1
   Clear Power Supply failure
 
4          2011/04/01 18:11:54.10  MINOR        7-2004-1      Fan 1
   Clear Fan wrong type failure
 
1          2011/04/01 18:11:54.00  CRITICAL     7-2007-1      Power Supply 1
   Clear Power Supply failure
===============================================================================